Page view 12
To Set Energy Saving Times Real Time Clock Functions (If Present) • 7
6.2. To Set Energy Saving
Times
6.3. To Set Timed Defrost
Parameters
ILE Energy Saving cycle
start during
workdays
(0 to 23 h 50 min)
During the Energy Sav-
ing cycle, the setpoint
is increased by the val-
ue in HES so that the
operation setpoint is
SET + HES.
dLE Energy Saving cycle
length during
workdays
(0 to 24 h 00 min) Sets
the duration of the En-
ergy Saving cycle on
workdays.
ISE Energy Saving cycle
start on holidays
(0 to 23h 50 min)
dSE Energy Saving cycle
length on holidays
(0 o 24h 00 min)
HES Temperature
increase during the
Energy
Saving cycle
(-30 to 30°C/ -54 to
54°F) Sets the increas-
ing value of the set-
point during the Energy
Saving cycle.
Table 6-2 - Energy Saving Times Parameters
Ld1
to
Ld6
Workday
defrost start
(0 to 23h 50 min) These param-
eters set the beginning of the
eight programmable defrost cy-
cles during workdays. For ex-
ample, when Ld2=12.4, the
second defrost starts at 12.40
during workdays.
Sd1
to
Sd6
Holiday
defrost start
(0 to 23h 50 min) These param-
eters set the beginning of the
eight programmable defrost cy-
cles during holidays. For exam-
ple, when Sd2=3.4, the second
defrost starts at 3.40 on holi-
days.
Table 6-3 - Timed Defrost Parameters
NOTE: To disable a defrost cycle, set it to nu
(not used). For example, if Ld6=nu, the sixth
defrost cycle is disabled.
Page view 12