3 Other Indications
Mains Fail: The AC supply to the system has failed
Charger Fault: Fuse failure, or insufficient voltage present.
Battery Fault: Battery may be disconnected, or discharged (may
be due to prolonged power cuts, alarm
conditions, etc.) If indication does not clear
within 4 hours, call your engineer.
Line Fault: Telephone line to the communicator has failed.
Engineer Reset If this message appears after an alarm, phone
Needed: your security company who will
arrange for an engineer to check and reset
the system. See 3.1
24hr Zone Open A zone which is continuously live (eg PA, Fire,
Zone x 24Hr Tamper) has not been cleared after
silencing an alarm. This must be done before
attempting to set the system.
Tamper Open A wiring or similar fault exists on the zone
Zone x shown, which must be corrected before the
system can be set.
System Tamper A wiring or similar fault exists on the system,
CALL ENGINEER which must be corrected before the system can be
set.
Attention! Accompanied by a 'chime' tone, indicates that a
Zone x zone configured as a 'chime' zone has been
activated. Refer to section 2.6 for details.
NOTE: Except for 'CHIME,' the indication will clear from the display after the condition to
which it refers has cleared. To clear the 'Chime' indication, use the 'NO' key to scroll around
the 'System Ready' menu. Any indications remaining will show that the fault remains current.
3.1 Engineer Reset Needed
If this message is displayed on the keypad, the system is locked out, and cannot be reused
until checked and reset by an engineer from your alarm company.
Under certain circumstances, your Alarm Receiving Centre may permit you to reset the
system without an Engineer being present. If this is possible, the keypad will also include a
special "anticode" in the form
Engineer Reset
Needed: 12345 CCT
To use this code, contact the Alarm Receiving Centre by telephone, and quote the 5-digit
"anticode" which is displayed - stating that you have a Castle 2300 (2500 or 2700) Control -
and wait for further instructions. A code will be supplied, which should be entered whilst the
'Engineer Reset' message is displayed. The code will function for this one occasion only.
Note: Depending upon how the system is programmed, any 'Personal Attack' facilities within
the system may be live although the system is locked out for normal use.