FAULT FINDING GUIDE
CUSTOMER HAD AN ALARM Ask them to press the Full set button and tell you
what indicators are on. The LED's indicate the cause of the alarm and also the setting
status at the time.
MAINS LED FLASHING Mains failure (Restore supply)
ZONE LED FLASHING (in exit) Check that doors and windows are closed.
Flashing with tamper LED. (A detector has an open tamper).
Flashing with Battery LED. (The detectors battery needs replacing).
ALARM LED ON Full alarm. The LEDs indicate what caused the alarm.
If Engineer reset is programmed into the panel an engineer reset will be required before
the system can be re-armed.
Flashing with zone LED A detector on soak test has triggered whilst the
system was armed.
Flashing without a zone LED An engineer reset is required.
BATTERY LED ON The control panel's battery is disconnected or needs replacement.
Flashing with zone LED Detector has a low battery. The zone LED will flash
to
indicate which one.
SIGNALLING LED ON The system is being blocked by a continuous transmission.
CONTACT TRANSMITTER NOT WORKING Check the magnetic contact is operating
correctly. Open lid and check what zone it should be on. Go into the panel engineer mode
and check if it has been programmed onto the correct zone.
Note: the panel will not allow you to program a detector onto two zones. When pro-
grammed onto a zone any previous zone allocation will be deleted.
PIR NOT WORKING The detector needs 6 minutes to settle on power up.
Set the control into operator walk test mode and walk test the detector with the
cover removed. Removing the cover opens the tamper and overrides the 2 minute inhibit
timer.
If the test jumper inside is fitted and the cover replaced it overrides the 2 minute inhibit,
but allows you to walk test it without a tamper alarm.
CUSTOMER HAS FORGOTTEN THEIR CODE Open the panel and short out the MEM
jumper. The user and engineer codes will be restored to the factory defaults 1234 & 4679.
No other programming is affected.
11
FM4000E
CONTROL PANEL
INSTALLATION INSTRUCTIONS
ZONES
FM Electronics Ltd Manufacturer of quality wireless products
CI-146 ISS 1
PANIC
FIRE
FULL SET
PART SET
OFF
SIGNALLING
LOW
BATTERY
ALARM
MAINS ON
TAMPER
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - CONTROL PANEL

FAULT FINDING GUIDECUSTOMER HAD AN ALARM Ask them to press the Full set button and tell youwhat indicators are on. The LED's indicate the cause

Page 2

++__56879432143215678ANTENNAGROUNDTAMPERMEMJumper+ LATCH-ve SIREN-ve STROBE-ve DIALLER17V a.c.InputEXITSOUNDERVolume leveladjustLink 5 to 4 if -vefrom

Page 3 - SAB CONNECTION TO THE FM4000

29Bell sw-Bell sw+Tamper feedTamper returnStrobe +Strobe --ve Hold off+ve Hold off71358Connections on the FM4000 main boardSAB CONNECTION TO THE FM40

Page 4 - PROGRAMMING

3 8PROGRAMMING1. Enter the engineers code 4 6 7 9The Alarm led will flash slowly to indicatethat you are in the program mode.2. Key in the two digi

Page 5 - * = FACTORY DEFAULT

471= Yes O= No*Press the full set key to exit.34 JAMMING1 = Jamming generates a full alarm whensetO= indicator only*Press the full set key to e

Page 6

6521 WALK THROUGH ZONESThe factory default is none.The zone LED's indicate which zones arewalk through during entry.Use the keys 1 to 8 to selec