BX2
Write Once Options
Reset write once rec.
Allow user reset
Minimum low disk
On disk full
Write once last reset at
Reset
Disabled
20% 0064GB
Overwrite
26/May/2005 09:48
Press MENU/MODE when done
Reset Write Once Record
This will reset the earliest ‘Write Once’ record time and date to the current time and date. This is necessary when
archiving has been successful and the process is to restart.
To reset the Write Once record option, hold down the Camera 1 button for 5 seconds.
Allow User Reset
This option will enable an Operator menu which will allow the operator to reset the Write Once record option.
This is can be accessed from the ‘Copy Images’ screen as a submenu.
Minimum Low Disk
This sets the minimum percentage disk space available. If the Write Once storage drops below this minimum
setting, an alarm is triggered (warning will be displayed on the main monitor) which will be cleared once more
disk space becomes available.
Note: This option is a percentage of the overall hard disk of the unit, the equivalent in Gigabytes will be
automatically calculated and displayed.
On Disk Full
This option determines what action the unit will take when the disks become full. The options are;
Overwrite - By default, the unit will overwrite the recorded images on the hard disk. A warning will
also be displayed to inform the Operator that the disk is full.
Stop Recording - The unit will stop recording. A warning will also be displayed.
Write Once Last Reset
This displays the time and date the Write Once process was last reset.
Schedule Rates
This option is enabled by default. With ‘Schedule Rates’ enabled, the unit provides the option to congure
record rates for day, night and weekend operating mode in the ‘Standard Record Schedule’ and ‘Variable Record
Schedule’ menu. Disabling this option will switch the scheduled recording options to a single set of rates to be
used in all schedule (day, night, weekend) operation modes.
Local 4CI4 Interlace
The paramter ‘Local 4C1F Interlace’ can be switched On if the system will be used to record using the 4C1F
settings. This will eliminate the comb effect that may be visible in a high motion recording environment. It is not
required if the unit is not utilizing 4C1F, it may also not be required if not reading high motion.
Page view 71
1 ... 71 72 73 ... 97

Comments to this Manuals

No comments