Code Alarm ca5553sst User Manual Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 49
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
2-
Factory
Disarm: Controls the timing of the
LT.
GREEN/BLACK factory disarm
output.
Factory Disarm - Single 1 second pulse with unlock and remote start
activation.
2nd Unlock - Same output as unlock with 2nd press of unlock. .
Start Status - Single 1 second pulse with unlock and continuous ( - ) output
during the remote start cycle.
NOTE:
On
this model the Lt Green I Black Output wire can
be
configured
in
Bank
3 or Bank
5.
Any changes to this feature
in
Bank 5 will override changes made
in
Bank
3.
3 -
Ignition
Controlled
Locks:
Control of door locks when the ignition is cycled
ON
or
OFF.
OFF-
Door locks not activated by ignition.
Lock and Unlock - Doors lock when ignition is turned
on
and unlock when
ignition is turned off.
Lock
Only-
Doors lock when ignition is turned on only.
Unlock Only Doors unlock when ignition is turned off only.
4 -
Trunk
Output
Timing
- Red/White
Output:
Controls the output timing/type
of the RED/WHITE output.
1 Second
Pulse-
1 second pulse output.
1 0 Second - Continuous output for 1 0 seconds.
20 Seconds - Continuous output for 20 seconds.
Latched until IGN
ON
- Continuous output until the vehicle's ignition is turned
ON.
Latched ON until Button Press - Continuous output until the activation button
is pressed again.
5 -
Horn
Output
Timing:
Control the minimum horn pulse time
in
milli seconds,
some vehicle will require a longer pulse to activate the factory horn.
16mS 1
OmS
30mS 40mS 50mS
6 - Real Panic: Controls the panic out when triggered from the transmitter.
ON
- Randomized horn honks when panic is triggered.
OFF - Standard pattern horn honks when panic is triggered.
2012 Audiovox Electronics Corporation. All rights reserved.