Code Alarm SRT 5500 Specifications Page 32

  • Download
  • Add to my manuals
  • Print
  • Page
    / 87
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 31
December 2013
REQUEST FOR PROPOSALS FOR
PURCHASE AND DELIVERY OF HEAVY-DUTY BUSES
RFP SRTA-2014-01
TECHNICAL SPECIFICATIONS
PAGE-32
process. The entire LED assembly shall be specially coated to protect the light
from chemical and abrasion degradation.
i. Bottom lamp (back-up lamp) shall be LED Dialight, or approved equal, with
removable acrylic clear lens, replaceable 32 c.p. bulb number 1156.
j. Side turn signal lamps shall be located on each side of the coach at the forward
edge of the front wheel housing. The side signal lights shall be Dialight, or
approved equal, amber 18 Series lights. These lights shall be guarded for
protection. The light shall be visable from the rear and front of the coach as
well as outward. All electrical connections to the LED light shall be by wire
coming from the light housing and terminated with a Packard Weather Pak
connector, or approved equal. No interim connector shall be allowed on the body
of the light. The same type side signal lamp shall be located slightly above and
slightly forward of the rear wheel housing.
k. Intermediate side marker lights shall be Dialight LED Series 84, or approved
equal, one on each side of coach.
l. Wheelchair ramp/kneeling light shall be Dialight, or approved equal, LED 2
inch diameter located adjacent to the front entrance door.
m. License plate lamp shall be Dialight, or approved equal, LED recessed in right
lower quadrant of the engine compartment door.
n. Curb Dialight, or approved equal, LED lights, or approved equal, shall be
positioned in manufacturer's standard location above the front and rear doors in
such a manner as to illuminate the ground area in the immediate vicinity of the
stepwell. Dialight, or approved equal, LED lights shall be actuated when
entrance door, exit door, or both, are opened.
o. Directional lamps shall be equipped for simultaneous flashing for emergency
use. They shall be controlled by a switch located on the Driver’s side console, or
from a mometary foot operated push buton switch located on the floor on the left
side of the steering column with the side turn buttons. The SRTA will approve
the final configuartion of the floor switch layout at the pre-production meeting.
14.18 Interior Lighting
a. Front and rear stepwells shall be lighted by Dialight, or approved equal, LED
suitably mounted so that entire stepwell and a portion of the ground area
immediately outside the coach is illuminated.
b. An overhead interior LED lighting system, Dinex, or approved equal, shall
provide general illumination in the passenger compartment and shall be
controlled independent of the run switch. The system shall provide a
minimum of 15 foot-candles of illuminance on a one square foot plane at an
angle of 45 degrees, centered 33 inches above the floor and 24 inches in front
of the seat back at each seating position. The floor surface in the vestibule
shall be illuminated at a minimum of 4 foot-candles with the front door open and
a minimum of 2 foot-candles with the front door closed. Lighting intensity for all
cross seats, forward of the rear longitudinal seats, shall have a minimum
average of 15 foot candles, with a minimum of 12 foot candles at the seated
passenger reading plane. An effective level of lighting shall also be provided
for all other seated passengers. The
Page view 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 86 87

Comments to this Manuals

No comments