REQUEST FOR PROPOSALS FOR
PURCHASE AND DELIVERY OF HEAVY-DUTY BUSES
RFP SRTA-2014-01
TECHNICAL SPECIFICATIONS
PAGE-35
e. The understructure shall incorporate minimum 3/16” steel floor material in the
area of the vestibule, the driver’s platform and the exit door area. The installation
shall be sufficiently rigid to prevent flexing, and to permit rigid mounting of a
farebox.
f. Understructure shall provide protected pathways for hydraulic lines, heater
piping, airlines and electrical cabling. PVC tubing shall be used as protective
conduit for wires and cables. Joints in lines, hoses, etc. shall be accessible for
repairing.
15.3 Construction: Exterior Panels
a. Body structure shall be modern, and aesthetically pleasing without protruding
fasteners. Visible exterior fasteners shall be kept to an absolute minimum.
b. Side panels below the window line shall be aluminum, etched, primed and
painted to the SRTA paint scheme. These side panels shall each be
replaceable by a mechanic without assistance. Welding, riveting, or adhesive
attachment is deemed unacceprable, although adhesive, as a secondary method
to control panel resonance will be permitted.
c. All side panels shall be essentially flat, without ripples and with minimal visible
joints.
d. Side panels shall be simple enough in shape to allow fabrication with no more
tooling than a shear brake and edge roller. Metal panels with compound curves,
fluting, curved indentations, etc. will not be permitted.
15.4 Construction: Hardware
Fasteners must be of non-corroding material or finished to prevent rust and corrosion.
Boron fasteners are not acceptable.
15.5 Insulation
a. Interior of body, including roof, must be well insulated against heat, cold and
noise.
b. Roof insulation shall polystyrene EPS insulation.
c. Sidewall insulation shall meet the same specifications as roof insulation. It shall
be installed in all sidewalls, window post areas, and areas over the front and rear
wheelhouses.
d. The insulation referred to above, or other additional insulation, shall provide
effective sound attenuation for the passenger.
e. There shall be Barymat BYUF-14C 1” foam insulation, or approved equal, in the
engine compartment to restrict, to the maximum practical extent, the entry of
fumes, odors and heat into the passenger area.
15.6 Flooring: Plywood